Background: Total hip arthroplasty (THA) is one of the most successful orthopedic procedures for relieving pain and restoring function in patients with end-stage hip diseases. Bearing surface selection plays a critical role in implant longevity, wear characteristics, osteolysis, and functional outcomes. Ceramic-on-ceramic (CoC) and ceramic-on-polyethylene (CoP) bearings are widely used modern options, each with distinct biomechanical properties and clinical implications. While CoC bearings offer excellent wear resistance and reduced osteolysis, concerns remain regarding squeaking and ceramic fracture. Conversely, CoP bearings have evolved with highly cross-linked polyethylene, potentially reducing wear-related complications. Comparative clinical evidence remains necessary to guide optimal bearing selection.
Objective: To compare clinical outcomes, complication rates, and implant performance between ceramic-on-ceramic and ceramic-on-polyethylene bearing surfaces in patients undergoing primary total hip arthroplasty.
Methodology: A comparative analytical study was conducted at Sughra Shafi Medical Complex Narowal from July 2024 to June 2025 as of one year time involving patients who underwent primary THA using either CoC or CoP bearing surfaces. Patients were allocated into two groups based on the bearing type. Demographic data, operative details, and postoperative follow-up outcomes were recorded. Clinical outcomes were assessed using standardized hip function scores, including pain relief, range of motion, and functional mobility. Radiographic evaluation was performed to assess component positioning, wear, and signs of osteolysis or loosening. Complications such as dislocation, squeaking, infection, and revision surgery were documented. Statistical analysis was performed to compare outcomes between the two groups, with significance set at p < 0.05.
Results: Both groups demonstrated significant improvement in postoperative functional scores compared to preoperative status. The CoC group showed lower radiographic wear and absence of polyethylene-related osteolysis, while the CoP group demonstrated comparable functional outcomes with fewer reports of audible phenomena. Complication rates were low in both groups, with no statistically significant difference in infection or dislocation rates. Squeaking was observed exclusively in the CoC group, whereas mild radiographic wear was noted in some CoP cases without clinical significance.
Conclusion: Both ceramic-on-ceramic and ceramic-on-polyethylene bearings provide excellent clinical and functional outcomes in total hip arthroplasty. CoC bearings offer superior wear resistance, while CoP bearings provide reliable performance with fewer bearing-specific complications. Bearing selection should be individualized based on patient factors, surgeon preference, and long-term outcome considerations.
References
2. Oger R, Hulet C, Tripon M, Dunet J, Faure P-A, Dartus J, et al. Should Ceramic-on-Ceramic or Ceramic-on-Polyethylene Bearings Be Preferred in Revision Total Hip Arthroplasty After Ceramic Head or Liner Fracture? A Retrospective Multicenter Case-Control Study of 33 Cases. Orthopaedics & Traumatology: Surgery & Research. 2025:104426.
3. van Loon J, Hoornenborg D, van der Vis HM, Sierevelt IN, Opdam KT, Kerkhoffs GM, et al. Ceramic-on-ceramic vs ceramic-on-polyethylene, a comparative study with 10-year follow-up. World Journal of Orthopedics. 2021;12(1):14.
4. Fang Y, Shang X. Comparison of ceramic-on-ceramic vs. ceramic-on-polyethylene for primary total hip arthroplasty: a meta-analysis of 15 randomized trials. Frontiers in Surgery. 2021;8:751121.
5. Van Loon J, De Graeff JJ, Sierevelt IN, Opdam KTM, Poolman RW, Kerkhoffs GMMJ, et al. Revision in ceramic-on-ceramic and ceramic-on-polyethylene bearing in primary total hip arthroplasty with press-fit cups: a systematic review and meta-analysis of different methodological study designs. Archives of Bone and Joint Surgery. 2022;10(11):916.
6. Almaawi A, Alzuhair A, AlHakbani A, Benfaris D, Al-Abdullatif F, Alabdulkarim NH, et al. Comparison of ceramic-on-ceramic and ceramic-on-highly-crosslinked-polyethylene in primary total hip arthroplasty: findings of a meta-analysis. Cureus. 2021;13(2).
7. Spir IAZ, Anzai A, Utino A, Katayama H, Tosello G, Nery MM, et al. Comparison between ceramic-on-polyethylene versus metal-on-polyethylene prostheses in Total Hip Arthroplasties: a systematic review and meta-analysis. Revista da Associação Médica Brasileira. 2022;68(12):1611-8.
8. Miranda I, Chiappe C, Valverde-Vázquez R, Miranda FJ, Doménech J. Outcomes following primary total hip arthroplasty with ceramic-on-metal and metal-on-metal bearings. Archives of Orthopaedic and Trauma Surgery. 2025;145(1):435.
9. Solarino G, Spinarelli A, Virgilio A, Simone F, Baglioni M, Moretti B. Outcomes of ceramic composite in total hip replacement bearings: a single-center series. Journal of Composites Science. 2021;5(12):320.
10. Shahin M. Hard-on-hard bearings in total hip arthroplasty for young active and patients with osteoarthritis. 2022.
van Loon J, Sierevelt IN, Spekenbrink-Spooren A, Opdam KT, Poolman RW, Kerkhoffs GM, et al. Higher risk of 2-year cup revision of ceramic-on-ceramic versus ceramic-on-polyethylene bearing: analysis of 33,454 primary press-fit total hip arthroplasties registered in the Dutch Arthroplasty Register (LROI). Hip International. 2023;33(2):280-7.
11. Donaire Hoyas D, Jiménez Mejías E, Moreta J, Sumillera García M, Albert Ullibarri A, Albareda Albareda J. A Comparison Between Two Bearing Surfaces for Total Hip Arthroplasty—Ceramic-on-Ceramic and Metal–Polycarbonate–Urethane—A Pseudo-Randomized Study. Journal of Functional Biomaterials. 2025;16(10):371.
12. Cordero-Ampuero J, Velasco P, Payo-Rodríguez J, Peñalver-Andrada P, González-Fernández E. Ceramic-on-ceramic vs metal-on-crosslink polyethylene in a fully hydroxyapatite-coated total hip arthroplasty: Survivorship, complications and long-term results. Journal of Clinical Orthopaedics and Trauma. 2024;57:102555.
13. Sweeney P, Broderick J. A systematic review and meta-analysis of cases of prosthetic hip-associated cobalt toxicity in patients with prosthetic hip ceramic bearing fractures subsequently revised to metal-on-polyethylene implants. Journal of Orthopaedics. 2025.
14. Triantafyllou A, Papagiannis G, Stasi S, Georgios P, Koulouvaris P, Papagelopoulos PJ, et al. Biomechanical assessment of wear in ceramic on ceramic and ceramic on xlpe THAs. Journal of Mechanics in Medicine and Biology. 2021;21(02):2150023.
15. McEntire BJ, Bal BS, Pezzotti G. A Critical Review of Two Bioceramics for Total Hip Arthroplasty. Silicon Nitride Bioceramics. 2024:327-74.